SNMP Alarms in Syslog
SNMP alarms are sent to the Syslog server using the following format.
| ■ | Sent alarms: RAISE-ALARM: <Alarm Name>; Textual Description: <Textual Description>; Severity <Alarm Severity>; Source <Alarm Source>; Unique ID: <Alarm Unique ID >. |
If additional information exists in the alarm, the following are also added: Additional Info1:/ Additional Info2:/ Additional Info3
The message severity is as follows:
Message Severity
|
ITU Perceived Severity (SNMP Alarm’s Severity) |
AudioCodes Syslog Severity |
|---|---|
|
Critical |
RecoverableMsg |
|
Major |
RecoverableMsg |
|
Minor |
RecoverableMsg |
|
Warning |
Notice |
|
Indeterminate |
Notice |
|
Cleared |
Notice |
| ■ | Cleared alarm: |
CLEAR-ALARM: <Alarm Name>; Textual Description: <Textual Description>; Severity <Alarm Severity>; Source <Alarm Source>; Unique ID: <Alarm Unique ID >; If exists Additional Info1:/ Additional Info2:/ Additional Info3: